Factory DirectFree Freight on Orders $1,500+
Contact Support|
HF
How to Build FenceProfessional DIY & Kits
Commercial & Industrial Security Chain Link componentsCAD CL-01 / CL-08 / CL-24 • ASTM F1083 Schedule 40 Hot-Dip Galvanized & ASTM F1043 High-Strength Group IC

Line Posts, Terminal Posts & Flange Plates

1-5/8" and 1-7/8" line posts, 2-3/8" and 2-7/8" terminal/corner/gate posts for in-ground concrete embedment or surface-mount welded floor flange plates.

Verified Component Inventory

2 items cataloged
Pro-Grade Commercial SupplySKU: HTBF-033029
4" x 10' Commercial Grade Galvanized Post (ASTM F1043 Group IC)

4" x 10' Commercial Grade Galvanized Post (ASTM F1043 Group IC)

4" OD x 10' Heavy Commercial Grade Commercial Post

Pro-Grade Commercial SupplySKU: HTBF-033078
2-7/8" x 9' Commercial Grade Galvanized Post (ASTM F1043 Group IC)

2-7/8" x 9' Commercial Grade Galvanized Post (ASTM F1043 Group IC)

2-7/8" OD x 9' Heavy Commercial Grade Commercial Terminal Post

Engineering Submittal & Sizing Guide

CLFMI CLFS 2445 Footing Embedment & Outside Diameter (OD) Pipe Schedule

Per CLFMI CLFS 2445 §3.2A, minimum concrete footing depth is 24 inches for a 4ft fence plus 3 additional inches for every foot of fence height above 4ft. Line posts are spaced at a maximum of 10 feet on-center.

Applicable Standards
ASTM F1083 Schedule 40 Hot-Dip Galvanized & ASTM F1043 High-Strength Group IC
Actual Outside Diameter (OD) Scale Across Line, Terminal & Gate Posts

Actual Outside Diameter (OD) Scale Across Line, Terminal & Gate Posts

1-5/8" OD Res. Line Post → 1-7/8" OD Comm. Line Post → 2-3/8" & 2-7/8" OD Terminal Posts → 4" OD Gate Post.

Multi-Layer Zinc & Polymer Corrosion Protection Architecture

Multi-Layer Zinc & Polymer Corrosion Protection Architecture

Hot-dip galvanized (1.8 oz/ft² ASTM F1083) and triple-coated high-strength Group IC structural tubing.

Fence HeightMin. Footing Depth (CLFMI)Order Post Total LengthRecommended Pipe OD (Line / Terminal)
4 ft (48")24" Deep × 8"–10" Ø6 ft to 7 ft (72"–84")1-5/8" OD Line / 2-3/8" OD Terminal
5 ft (60")27" Deep × 10" Ø7 ft to 8 ft (84"–96")1-5/8" OD Line / 2-3/8" OD Terminal
6 ft (72")30" Deep × 10"–12" Ø8 ft to 9 ft (96"–108")1-5/8" or 1-7/8" Line / 2-3/8" or 2-7/8" Term.
8 ft (96")36" Deep × 12" Ø10 ft to 11 ft (120"–132")1-7/8" or 2-3/8" Line / 2-7/8" or 4" Sch 40 Term.
Frequently Asked Technical Questions — Posts & Surface Mounting

How deep should chain-link fence posts be set in concrete?

Per CLFMI CLFS 2445 §3.2A, set posts at least 24" deep for a 4ft fence, 27" deep for a 5ft fence, 30" deep for a 6ft fence, and 36" deep for an 8ft commercial fence—or below the local frost line, whichever is deeper.

When should I use a welded floor flange plate instead of burying posts?

Use a heavy-duty welded steel floor flange plate anchored with four 1/2" × 4-1/4" concrete wedge anchors when mounting 3ft to 6ft chain-link posts directly onto an existing structural concrete slab, retaining wall cap, or loading dock.

Need Exact Quantities?

Use Our Interactive Layout Builder

Don't guess how many posts, rails, caps, or fabric rolls you need. Draw your fence layout on our interactive canvas, configure your heights and finishes, and get a complete, accurate, commercial-grade bill of materials instantly.

Launch 2D Layout Tool